| LV SERIES |
|
Low Vacuum Oil Conditioner |
![]() LV-600-AX-32-A/C/WM |
![]() LV-360-AX-16-B/WM |
| Model No. & Flow GPH | LV-60c | LV-120 | LV-360 | LV-600 | LV-900 | LV-1200 | LV-1800 | LV-2400 |
| Heater Capacity KW | 6 | 12 | 16 | 32 | 48 | 64 | 96 | 128 |
| Total Power Required KW | 8 | 15 | 19 | 35 | 54 | 70 | 102 | 138 |
| Motor HP, Oil Discharge Pump | 1/3 | 1/3 | 1 | 1 | 1 1/2 | 1 1/2 | 2 | 3 |
| Quantity Coalescers #GC-1635 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Quantity Coalescers #GC-3135 | 0 | 2 | 5 | 10 | 12 | 14 | 20 | 24 |
| Oil Discharge Pressure Range | Adjustable Standard Unit Range ............................................ 10 - 50 PSI | |||||||
|
· All power calculations are for 480 Volts, 3 Phase, 50 / 60 Hz · Each GEI Unit is equipped with an Internal Transformer to supply 120V Single Phase power for the control voltage. · There are three basic vacuum system types available with many variations within each type. For example: · Vacuum Pump · Liquid Ring Vacuum Pump · Ejector Type Vacuum System (See Water Miser Section) |
||||||||
Rental Fleet - LV-600-AX-32-WM |
| Model No. & Flow GPH | LV-60-V | LV-120 | LV-360 | LV-600 | LV-900 | LV-1200 | LV-1800 | LV-2400 |
| Oil Inlet Size NPT | 1/2 | 3/4 | 1 | 1 1/2 | 1 1/2 | 1 1/2 | 2 | 2 |
| Oil Outlet Size NPT | 1/2 | 1/2 | 3/4 | 1 | 1 1/2 | 1 1/2 | 2 | 2 |
| Coolant Inlet Size NPT | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 |
| Coolant Outlet Size NPT | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 |
| Approximate Height | 52 | 66 | 66 | 66 | 70 | 70 | 72 | 72 |
| Approximate Length | 42 | 66 | 72 | 72 | 96 | 96 | 120 | 240 |
| Approximate Width | 42 | 48 | 52 | 60 | 72 | 72 | 84 | 90 |
| Approximate Weight | 750 | 1000 | 1800 | 2300 | 2650 | 3000 | Consult Factory | |
| Skid Sizes Vary With Options. | ||||||||
|
|
|
|